This rice cooker has a tool commonly used by the public as a practical function that can cook rice and warm it.

6 An important part magic jar:

     Two indicator lights are located on the underside of the body magic jar. consists of pilot lights cook / cook red and indicator lamps to warm / warm usually yellow or green.
     Thermostate, temperature control is a component / heat that is located on the inside of the body magic jar.
     Thermofuse, functions like a fuse that will drop out at a temperature that exceeds the tolerance limit, it is in the body magic jar.
     Body elements, functions for cooking rice lying around the body part in a magic jar.
     Element caps, function warms rice, located in the magic jar lid.
     Connecting cable.


How it works magic jar;

     When cooking rice cable plugged in and the indicator light (warm) and then turn on the switch is pressed and the indicator light cooking / cook on.
     Electricity flows from the cable to the thermostate, thermofuse, elements of the body and the lid element.
     Electrified elements will heat up and will cook the rice to a certain temperature.
     When the rice is cooked at a certain temperature it will affect the thermostate and will decide electric current to the body element which will be shown with the migration position on the mode switch to the warm (warm) and death indicator light cooking (cook).
     Furthermore Thermostate will regulate the temperature inside the jar so that majic stable at warmer temperatures.


Complaints that often arise and cause:

     Total dead, cause: Thermofuse connecting cable may break up or break up from being bitten by rats.
     Quick rice yellow / odor, causes: elements lid broken or burned.
     Rice dry quickly, cause: thermostate dirty or blocked or damaged by age.
     Not hot either cooking or warming, causes: body element or cause fire.
     Button does not lock when cooking rice or not back it up (warm position) when the rice is ripe, cause: thermostate dirty, nothing is blocking or damaged due to age.


How to open the lid elements:

     Open and remove the screws from the body
     disconnect the cord
     remove the cap from its elements.


How to unlock the body element:

     Open baud at the bottom of the jar and poke magic interposed between the central body with the lower body cover using a screwdriver min.
     after closing lower body regardless sedkeliling look at the inside of the body, there is no element wrapped in aluminum foil body (like duct tape), disconnect the cable and take the element.